Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Asunto principal
Intervalo de año de publicación
1.
Am J Otolaryngol ; 45(4): 104260, 2024 Mar 18.
Artículo en Inglés | MEDLINE | ID: mdl-38613928

RESUMEN

OBJECTIVE: The aim of the study was to trace the development of surgical therapy in a large cohort, examine its changes at one single institution that has been specializing in salivary gland pathologies over the last 22 years, and to determine the extent to which a possible shift in the surgical therapy of parotid benign tumors towards less radical methods was correlated with a change in the incidence of facial palsy and Frey's syndrome. STUDY DESIGN: Retrospective clinical study. METHODS: A retrospective evaluation of the records of all patients treated for benign parotid tumors at a tertiary referral center between 2000 and 2022 was carried out. Surgical methods were classified into four groups: extracapsular dissection, partial superficial parotidectomy, superficial parotidectomy and complete parotidectomy. RESULTS: A total of 4037 patients were included in the study. Our analysis demonstrated an increase in the total number of parotidectomies for benign lesions from 71 (2000) to 298 (2022), mostly due to the increase in extracapsular dissections (from 9 to 212). The increased performance of less radical surgery was associated with a significantly decreased incidence of perioperative complications. CONCLUSIONS: Our study showed that the increased performance of less radical surgery was associated with better functional outcomes over the years.

2.
Tomography ; 9(2): 579-588, 2023 03 05.
Artículo en Inglés | MEDLINE | ID: mdl-36961006

RESUMEN

Orbital floor fractures represent a common fracture type of the midface and are standardly diagnosed clinically as well as radiologically using linear measurement methods. The aim of this study was to evaluate the accuracy of diagnostic measurements of isolated orbital floor fractures based on two-dimensional (2D) and three-dimensional (3D) measurement techniques. A cohort of 177 patients was retrospectively and multi-centrically evaluated after surgical treatment of an orbital floor fracture between 2010 and 2020. In addition to 2D and 3D measurements of the fracture area, further fracture-related parameters were investigated. Calculated fracture areas using the 2D measurement technique revealed an average area of 287.59 mm2, whereas the 3D measurement showed fracture areas with a significantly larger average value of 374.16 mm2 (p < 0.001). On average, the 3D measurements were 1.53-fold larger compared to the 2D measurements. This was observed in 145 patients, whereas only 32 patients showed smaller values in the 3D-based approach. However, the process duration of the 3D measurement took approximately twice as long as the 2D-based procedure. Nonetheless, 3D-based measurement of orbital floor defects provides a more accurate estimation of the fracture area than the 2D-based procedure and can be helpful in determining the indication and planning the surgical procedure.


Asunto(s)
Fracturas Orbitales , Humanos , Estudios Retrospectivos , Fracturas Orbitales/diagnóstico por imagen , Fracturas Orbitales/cirugía , Órbita/cirugía , Tomografía Computarizada por Rayos X/métodos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...